Ugly's electrical references / (Record no. 10884)

000 -LEADER
fixed length control field 11379cam a2200493Ia 4500
001 - CONTROL NUMBER
control field u11454
003 - CONTROL NUMBER IDENTIFIER
control field SA-PMU
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210418125017.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110104s2012 maua f 001 0 eng
040 ## - CATALOGING SOURCE
Original cataloging agency GO9
Language of cataloging eng
Transcribing agency GO9
Modifying agency CUMCL
-- NFP
-- BTCTA
-- YDXCP
-- BDX
-- EDK
-- FER
-- OCLCF
-- OCL
-- OCLCQ
019 ## -
-- 630475644
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9780763790998
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 0763790990
035 ## - SYSTEM CONTROL NUMBER
System control number (OCoLC)694896046
Canceled/invalid control number (OCoLC)630475644
050 #4 - LIBRARY OF CONGRESS CALL NUMBER
Classification number TK151
Item number H28 2012
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 621.319 HART, G
029 1# - OTHER SYSTEM CONTROL NUMBER (OCLC)
OCLC library identifier NZ1
System control number 13839459
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Hart, George V.
245 10 - TITLE STATEMENT
Title Ugly's electrical references /
Statement of responsibility, etc. by George V. Hart and Sammie Hart ; William C. Buchanan, editor.
246 3# - VARYING FORM OF TITLE
Title proper/short title Electrical references
250 ## - EDITION STATEMENT
Edition statement 2011 ed.
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Sudbury, MA :
Name of publisher, distributor, etc. Jones and Bartlett,
Date of publication, distribution, etc. ©2012.
300 ## - PHYSICAL DESCRIPTION
Extent x, 195 pages :
Other physical details illustrations ;
Dimensions 16 cm
336 ## - CONTENT TYPE
Content type term text
Content type code txt
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Media type code n
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Carrier type code nc
Source rdacarrier
500 ## - GENERAL NOTE
General note Includes index.
505 0# - FORMATTED CONTENTS NOTE
Formatted contents note Circuits: -- OHM's law -- Series circuits -- Parallel circuits -- Combination circuits -- Common Electrical Distribution Systems: -- 120/240 volt, single-phase, three-wire system -- 120/240 volt, three-phase, four-wire system (Delta high leg) -- 120/208 volt, three-phase, four-wire system (WYE connected) -- 277/480 volt, three-phase, four wire system (WYE connected) -- Electrical Formulas: -- For calculating amperes, horsepower, kilowatts, and KVA -- To Find: -- Amperes -- Direct current -- Single phase -- Three phase -- Horsepower -- Direct current -- Single phase -- Three phase -- Watts -- Kilowatts -- Direct current -- Single phase -- Three phase -- Kilovolt-amperes -- Single phase -- Three phase -- Kirchhoff's laws -- Capacitance (C) -- Six-dot color code for mica and molded paper capacitors -- Resistor color code -- Maximum permissible capacitor kvar -- For use with open-type, three-phase, 60-cycle induction motors -- Power factor correction -- Table values x KW of capacitors -- Needed to correct from existing to desired power factor -- Power factor and efficiency example -- Inductance (L) -- Impedance (Z) -- Reactance (X) -- Motors: -- Full-load current in amperes: direct-current motors -- Direct-current motors -- Terminal markings -- Shunt-wound motors -- Series-wound motors -- Compound-wound motors -- Full-load current in amperes: single-phase alternating-current motors -- Single-phase motor using standard three-phase starter -- Single-phase motors split-phase, squirrel-cage, dual-voltage motor -- Classes of single-phase motors -- Terminal color marking -- Split-phase, squirrel-cage motor -- Running-phase, squirrel-cage motor -- Running overload units -- Motor branch-circuit protective devices: maximum rating or setting -- Full-load current: three-phase alternating-current motors -- Full-load current and other data: three-phase AC motors -- Motor and motor circuit conductor protection -- General motor rules -- Motor branch circuit and feeder example -- General motor applications -- Branch-circuit conductors -- Branch-circuit overcurrent device -- Feeder connectors -- Feeder overcurrent device -- Locked-rotor code letters -- Single-phase motors -- Three-phase motors -- Maximum motor locked-rotor current in ampepes single phase -- Maximum motor locked-rotor current in amperes, two and three phase, design B, C, and D -- Three-phase AC motor windings and connections -- Three-wire stop-start station -- Two three-wire stop-start stations -- Hand off automatic control -- Jogging with control relay -- Transformers: -- Voltage drop calculations: inductance negligible -- Single-phase circuits -- Three-phase circuits -- Voltage drop examples -- Distance (one-way) for 2% voltage drop -- For 120 or 240 volts-single phase (60 C [140 F] insulation and terminals) -- Typical voltage drop values based on conductor size and one-way length (60 C [140 F] termination and insulation) -- Voltage drop calculation examples -- Single-phase voltage drop -- Three-phase voltage drop -- Short-circuit calculation -- Basic short-circuit calculation procedure -- Example: short-circuit calculation table "C" values for conductors (short-circuit calculation) -- Component protection -- How to use current-limitation charts -- How to use let-through charts -- Single-phase transformer connections -- Buck-and-boost transformer connections -- Full-load currents -- Transformer calculations -- Sizing transformers -- Single-phase transformers -- Three-phase transformers -- Single-phase transformer -- Primary and secondary amperes -- Three-phase transformer -- Primary and secondary amperes -- Three-phase connections -- WYE (star) -- Delta -- Three-phase standard phase rotation -- Star-delta transformers -- Star-star transformers -- Delta-delta transformers -- Transformer connections -- Series connections of low-voltage windings -- Delta-delta: three-phase additive polarity -- Star-delta: three phase additive polarity -- Delta star: three phase additive polarity -- Star-star: three-phase additive polarity -- Delta-delta: three-phase subtractive polarity -- Delta-star: three-phase subtractive polarity -- Miscellaneous Wiring Diagrams: -- Two three-way switches -- Two three-way switches and one four-way switch -- Bell circuit -- Remote-control circuit: one relay and one switch.
505 0# - FORMATTED CONTENTS NOTE
Formatted contents note Conduit And Conductors: -- Supports for rigid metal conduit -- Supports for rigid nonmetallic conduit -- Conductor properties -- AC resistance and reactance for 600-volt cables, three-phase, 60-hz, 75 C (167 F): three single conductors in conduit -- Allowable ampacities of conductors -- Raceway, cable, or earth, based on ambient air temperature of 30 C (86 F) -- Free air, based on ambient air temperature of 30 C (86 F) -- Raceway or cable, based on ambient air temperature of 40 C (140 F) -- Free air, based on ambient air temperature of 40 C (104 F) -- Ampacity correction and adjustment factors -- Adjustment factors -- For more than three current-carrying conductors in a raceway or cable conductor and equipment termination ratings -- Conductor applications and insulations -- Maximum number of conductors in trade sizes of conduit or tubing -- All same wire size and type insulation -- Different wire sizes or types insulation -- Electrical metallic tubing -- Nonmetallic tubing -- Rigid PVC conduit, schedule 40 -- Rigid PVC conduit, schedule 80 -- Rigid metal conduit -- Flexible metal conduit -- Liquidtight flexible metal conduit -- Dimensions of insulated conductors and fixture wires -- Compact copper and aluminum building wire nominal dimensions and areas -- Dimensions and percent area of conduit and tubing -- Thread dimensions and tap drill sizes -- Hole saw chart -- Metal boxes -- Minimum cover requirements, 0-600 volts, normal -- Volume required per conductor -- Spacings for conductor supports -- General Electrical Tables: -- Minimum depth of clear working space at electrical equipment -- Minimum clearance of live parts -- Minimum size equipment grounding conductors for grounding raceway and equipment -- Grounding electrode conductor for alternating-current systems -- General lighting loads by occupancy -- Lighting load demand factors -- Demand factors -- For nondwelling receptacle loads -- For household electric clothes dryers -- For kitchen equipment-other than dwelling units(s) -- Demand loads for household electric rangers, wall-mounted ovens, counter-mounted cooking units, and other household cooking appliances over 1 3/4 KW rating -- Calculating cost of operating an electrical appliance -- Changing incandescent lamp to energy-saving lamp -- Partial 2011 NEC code change summary -- Field terms versus NEC terms -- Electrical symbols -- Wiring diagrams for NEMS configurations -- NEMA enclosure types -- General Reference: -- U S weights and measures -- Metric system -- Metric designator and trade sizes -- U S weights and measures/metric equivalent chart -- Explanation of scientific notation -- Useful conversions/equivalents -- Decimal equivalents -- Two-way conversion table -- Metals -- Specific resistance -- Centigrade and Fahrenheit thermometer scales -- Math Reference: -- Useful math formulas -- Circle -- Fractions -- Equations -- Natural trigonometric functions -- Trigonometry -- Conduit Bending: -- Bending offsets with trigonometry -- Rolling offsets -- Chicago-type benders: 90 degree bending -- Chicago-type benders: offsets -- Multi-shot benders: 90 degree conduit bending -- Offset bends -- 90 degree bends -- Back-to-back bends -- Three-point saddle bends -- Job-Site Reference: -- Pulley calculations -- Useful knots -- Hand signals -- Electrical Safety: -- Definitions -- Checklist -- Lock-out-tagout procedures -- Shock protection boundaries -- How to read a warning label -- Personal protection equipment guide -- Alternative Energy: -- Engine-generation systems -- Solar photovoltaic systems -- Wind turbines -- Fuel cells -- Microturbines -- Interconnected generation systems -- First Aid: -- Scene survey -- How to call for help -- Bleeding -- Ingested poisoning -- Recognizing ingested poisoning -- Care for ingested poisoning -- Shock -- Recognizing shock -- Care for shock -- Burns -- Care for burns -- Electrical burns -- Frostbite -- Recognizing frostbite -- Care for frostbite -- Hypothermia -- Recognizing hypothermia -- Care for hypothermia -- Heat cramps -- Recognizing heat cramps -- Care for heat cramps -- Heat exhaustion -- Recognizing heat exhaustion -- Care for heat exhaustion -- Heatstroke -- Recognizing heatstroke -- Care for heatstroke -- Airway obstruction -- Management of choking responsive -- Victim -- Adult cardiopulmonary resuscitation (CPR) -- Heart attack -- Recognizing a heart attack -- Care for a heart attack -- Stroke -- Recognizing a stroke -- Care for a stroke -- 2011-2013 calendars.
520 ## - SUMMARY, ETC.
Summary, etc. Synopsis: Ugly's Electrical References Is Designed To Be Used As An On-The-Job Reference. Used Worldwide By Electricians, Engineers, Contractors, Designers, Maintenance Workers, Instructors, And The Military; Ugly's Contains The Most Commonly Required Electrical Information In An Easy-To-Read And Easy-To-Access Format. Ugly's Presents A Succinct Portrait Of The Most Pertinent Information All Electricians Need At Their Fingertips, Including: Mathematical Formulas, National Electrical Code Tables, Wiring Configurations, Conduit Bending, Voltage Drops, And Life-Saving First Aid Procedures. Revised For The 2011 National Electrical Code, Ugly's Electrical References Includes Updated Coverage Of: Combination Circuits Conductor Properties Conduit Bending Conversion Tables Electrical Formulas Electrical Symbols Insulation Charts Math Formulas Metric System Ohm's Law Parallel Circuits Series Circuits US Weights And Measures Wiring Diagrams.
596 ## -
-- 1
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electrical engineering
Form subdivision Handbooks, manuals, etc.
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electrical engineering.
Source of heading or term fast
Authority record control number or standard number (OCoLC)fst01728596
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electrical engineering
Form subdivision Handbooks, manuals, etc.
Source of heading or term sears
655 #7 - INDEX TERM--GENRE/FORM
Genre/form data or focus term Handbooks and manuals.
Source of term fast
Authority record control number or standard number (OCoLC)fst01423877
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Hart, Sammie.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Buchanan, William C.
938 ## -
-- Brodart
-- BROD
-- 13024426
-- $18.95
938 ## -
-- Baker and Taylor
-- BTCP
-- BK0008991763
938 ## -
-- YBP Library Services
-- YANK
-- 3330469
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Books
994 ## -
-- Z0
-- SUPMU
948 ## - LOCAL PROCESSING INFORMATION (OCLC); SERIES PART DESIGNATOR (RLIN)
h (OCLC) NO HOLDINGS IN SUPMU - 94 OTHER HOLDINGS
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type Public note
          Main Library Main Library 04/18/2021   TK151 .H28 2012 51952000208259 04/15/2021 1 04/15/2021 Books STACKS