| 000 -LEADER |
| fixed length control field |
03490cam a22003614a 4500 |
| 001 - CONTROL NUMBER |
| control field |
u8774 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
SA-PMU |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20210418124552.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
020401s2002 nyua b 001 0 eng |
| 010 ## - LIBRARY OF CONGRESS CONTROL NUMBER |
| LC control number |
2002066455 |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
DLC |
| Language of cataloging |
eng |
| Transcribing agency |
DLC |
| Modifying agency |
UKM |
| -- |
C#P |
| -- |
UBA |
| -- |
BAKER |
| -- |
BTCTA |
| -- |
STF |
| -- |
YDXCP |
| -- |
OCLCG |
| -- |
DEBBG |
| -- |
EXW |
| -- |
IG# |
| -- |
OCLCQ |
| -- |
ILU |
| -- |
OCLCQ |
| -- |
TULIB |
| -- |
BDX |
| -- |
OCLCF |
| -- |
OCLCO |
| -- |
DEBSZ |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
0824707664 (alk. paper) |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
9780824707668 (alk. paper) |
| 035 ## - SYSTEM CONTROL NUMBER |
| System control number |
(OCoLC)49531028 |
| 042 ## - AUTHENTICATION CODE |
| Authentication code |
pcc |
| 050 00 - LIBRARY OF CONGRESS CALL NUMBER |
| Classification number |
TK2551 |
| Item number |
.W495 2002 |
| 082 00 - DEWEY DECIMAL CLASSIFICATION NUMBER |
| Classification number |
621.31/4 |
| Edition number |
21 |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Winders, John J., |
| Dates associated with a name |
1947- |
| 245 10 - TITLE STATEMENT |
| Title |
Power transformers : |
| Remainder of title |
principles and applications / |
| Statement of responsibility, etc. |
John J. Winders, Jr. |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
New York : |
| Name of publisher, distributor, etc. |
Marcel Dekker, |
| Date of publication, distribution, etc. |
c2002. |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xiii, 283 p. : |
| Other physical details |
ill. ; |
| Dimensions |
24 cm. |
| 490 1# - SERIES STATEMENT |
| Series statement |
Power engineering ; |
| Volume/sequential designation |
17 |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographical references and index. |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
| Additional physical form available note |
Also available on the Internet to registered users. |
| 505 00 - FORMATTED CONTENTS NOTE |
| Title |
Series Introduction / |
| Statement of responsibility |
H. Lee Willis -- |
| Title |
Basic Transformer Theory -- |
| -- |
Definition of a Transformer -- |
| -- |
Magnetic Units and Conversion Factors -- |
| -- |
Currents and Magnetic Fields -- |
| -- |
Magnetic Induction -- |
| -- |
Constructing a Simple Transformer -- |
| -- |
The Magnetic Circuit -- |
| -- |
The B-H Curve -- |
| -- |
The B-H Curve and Hysteresis -- |
| -- |
Magnetizing Currents and Harmonics -- |
| -- |
Transformer Core Design and Construction -- |
| -- |
Magnetostriction -- |
| -- |
Completing the Transformer by Adding a Second Winding -- |
| -- |
Placement of the Windings -- |
| -- |
Two-Winding Transformer Connections -- |
| -- |
The Y-Y Connection in Three-Phase Systems -- |
| -- |
Advantages of the Y-Y Connection -- |
| -- |
Disadvantages of the Y-Y Connection -- |
| -- |
The Y-[Delta] Connection and the [Delta]-Y Connection -- |
| -- |
Phase Angle Displacement and Phase Rotation -- |
| -- |
The Y-[Delta] Grounding Bank -- |
| -- |
The Zigzag Connection -- |
| -- |
Comparisons of Economy of the Different Winding Configurations -- |
| -- |
Trade-Off Between Steel and Copper in the Design of a Transformer -- |
| -- |
Connecting Three-Phase Banks Using Single-Phase Transformers -- |
| -- |
Transforming Three-Phase Voltages into Two-Phase Voltages -- |
| -- |
The Scott Transformer Connection -- |
| -- |
Three-Phase Transformer Designs -- |
| -- |
Standard Terminal Markings for Transformers -- |
| -- |
Transformer Impedance and Losses -- |
| -- |
Leakage Flux and Leakage Reactance -- |
| -- |
Conductor Losses -- |
| -- |
No-Load Losses -- |
| -- |
Magnetizing Reactance -- |
| -- |
Equivalent Circuit of a Two-Winding Transformer -- |
| -- |
A Brief Tutorial on Symmetrical Components -- |
| -- |
Transformer Equivalent Circuits Modeled in Zero Phase Sequence Networks -- |
| -- |
Series Impedance and Regulation. |
| 520 1# - SUMMARY, ETC. |
| Summary, etc. |
"Power Transformers features extensive coverage on zigzag, Scott, tee, wye, and delta connections ... tap changing under load and variable-phase shifting ... advantages and disadvantages in coil selection and construction ... symmetrical components ... transformer nameplate rating, thermal capability, and rate calculation of loss of life ... abnormal operating conditions such as overloads, short circuits, single phasing from primary fuse operations, ferroresonance, and voltage surges ... proper system design and selection to reduce faulty operation ... and preventive and predictive maintenance, good utility practices, factory and field testing, and failure rate analysis."--Jacket. |
| 596 ## - |
| -- |
1 |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Electric transformers. |
| 830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE |
| Uniform title |
Power engineering ; |
| Volume/sequential designation |
17. |
| 856 42 - ELECTRONIC LOCATION AND ACCESS |
| Materials specified |
Publisher description |
| Uniform Resource Identifier |
<a href="http://catdir.loc.gov/catdir/enhancements/fy0647/2002066455-d.html">http://catdir.loc.gov/catdir/enhancements/fy0647/2002066455-d.html</a> |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Koha item type |
Books |
| 994 ## - |
| -- |
Z0 |
| -- |
SUPMU |