000 11379cam a2200493Ia 4500
001 u11454
003 SA-PMU
005 20210418125017.0
008 110104s2012 maua f 001 0 eng
040 _aGO9
_beng
_cGO9
_dCUMCL
_dNFP
_dBTCTA
_dYDXCP
_dBDX
_dEDK
_dFER
_dOCLCF
_dOCL
_dOCLCQ
019 _a630475644
020 _a9780763790998
020 _a0763790990
035 _a(OCoLC)694896046
_z(OCoLC)630475644
050 4 _aTK151
_bH28 2012
082 0 4 _a621.319 HART, G
100 1 _aHart, George V.
245 1 0 _aUgly's electrical references /
_cby George V. Hart and Sammie Hart ; William C. Buchanan, editor.
246 3 _aElectrical references
250 _a2011 ed.
260 _aSudbury, MA :
_bJones and Bartlett,
_c©2012.
300 _ax, 195 pages :
_billustrations ;
_c16 cm
336 _atext
_btxt
_2rdacontent
337 _aunmediated
_bn
_2rdamedia
338 _avolume
_bnc
_2rdacarrier
500 _aIncludes index.
505 0 _aCircuits: -- OHM's law -- Series circuits -- Parallel circuits -- Combination circuits -- Common Electrical Distribution Systems: -- 120/240 volt, single-phase, three-wire system -- 120/240 volt, three-phase, four-wire system (Delta high leg) -- 120/208 volt, three-phase, four-wire system (WYE connected) -- 277/480 volt, three-phase, four wire system (WYE connected) -- Electrical Formulas: -- For calculating amperes, horsepower, kilowatts, and KVA -- To Find: -- Amperes -- Direct current -- Single phase -- Three phase -- Horsepower -- Direct current -- Single phase -- Three phase -- Watts -- Kilowatts -- Direct current -- Single phase -- Three phase -- Kilovolt-amperes -- Single phase -- Three phase -- Kirchhoff's laws -- Capacitance (C) -- Six-dot color code for mica and molded paper capacitors -- Resistor color code -- Maximum permissible capacitor kvar -- For use with open-type, three-phase, 60-cycle induction motors -- Power factor correction -- Table values x KW of capacitors -- Needed to correct from existing to desired power factor -- Power factor and efficiency example -- Inductance (L) -- Impedance (Z) -- Reactance (X) -- Motors: -- Full-load current in amperes: direct-current motors -- Direct-current motors -- Terminal markings -- Shunt-wound motors -- Series-wound motors -- Compound-wound motors -- Full-load current in amperes: single-phase alternating-current motors -- Single-phase motor using standard three-phase starter -- Single-phase motors split-phase, squirrel-cage, dual-voltage motor -- Classes of single-phase motors -- Terminal color marking -- Split-phase, squirrel-cage motor -- Running-phase, squirrel-cage motor -- Running overload units -- Motor branch-circuit protective devices: maximum rating or setting -- Full-load current: three-phase alternating-current motors -- Full-load current and other data: three-phase AC motors -- Motor and motor circuit conductor protection -- General motor rules -- Motor branch circuit and feeder example -- General motor applications -- Branch-circuit conductors -- Branch-circuit overcurrent device -- Feeder connectors -- Feeder overcurrent device -- Locked-rotor code letters -- Single-phase motors -- Three-phase motors -- Maximum motor locked-rotor current in ampepes single phase -- Maximum motor locked-rotor current in amperes, two and three phase, design B, C, and D -- Three-phase AC motor windings and connections -- Three-wire stop-start station -- Two three-wire stop-start stations -- Hand off automatic control -- Jogging with control relay -- Transformers: -- Voltage drop calculations: inductance negligible -- Single-phase circuits -- Three-phase circuits -- Voltage drop examples -- Distance (one-way) for 2% voltage drop -- For 120 or 240 volts-single phase (60 C [140 F] insulation and terminals) -- Typical voltage drop values based on conductor size and one-way length (60 C [140 F] termination and insulation) -- Voltage drop calculation examples -- Single-phase voltage drop -- Three-phase voltage drop -- Short-circuit calculation -- Basic short-circuit calculation procedure -- Example: short-circuit calculation table "C" values for conductors (short-circuit calculation) -- Component protection -- How to use current-limitation charts -- How to use let-through charts -- Single-phase transformer connections -- Buck-and-boost transformer connections -- Full-load currents -- Transformer calculations -- Sizing transformers -- Single-phase transformers -- Three-phase transformers -- Single-phase transformer -- Primary and secondary amperes -- Three-phase transformer -- Primary and secondary amperes -- Three-phase connections -- WYE (star) -- Delta -- Three-phase standard phase rotation -- Star-delta transformers -- Star-star transformers -- Delta-delta transformers -- Transformer connections -- Series connections of low-voltage windings -- Delta-delta: three-phase additive polarity -- Star-delta: three phase additive polarity -- Delta star: three phase additive polarity -- Star-star: three-phase additive polarity -- Delta-delta: three-phase subtractive polarity -- Delta-star: three-phase subtractive polarity -- Miscellaneous Wiring Diagrams: -- Two three-way switches -- Two three-way switches and one four-way switch -- Bell circuit -- Remote-control circuit: one relay and one switch.
505 0 _aConduit And Conductors: -- Supports for rigid metal conduit -- Supports for rigid nonmetallic conduit -- Conductor properties -- AC resistance and reactance for 600-volt cables, three-phase, 60-hz, 75 C (167 F): three single conductors in conduit -- Allowable ampacities of conductors -- Raceway, cable, or earth, based on ambient air temperature of 30 C (86 F) -- Free air, based on ambient air temperature of 30 C (86 F) -- Raceway or cable, based on ambient air temperature of 40 C (140 F) -- Free air, based on ambient air temperature of 40 C (104 F) -- Ampacity correction and adjustment factors -- Adjustment factors -- For more than three current-carrying conductors in a raceway or cable conductor and equipment termination ratings -- Conductor applications and insulations -- Maximum number of conductors in trade sizes of conduit or tubing -- All same wire size and type insulation -- Different wire sizes or types insulation -- Electrical metallic tubing -- Nonmetallic tubing -- Rigid PVC conduit, schedule 40 -- Rigid PVC conduit, schedule 80 -- Rigid metal conduit -- Flexible metal conduit -- Liquidtight flexible metal conduit -- Dimensions of insulated conductors and fixture wires -- Compact copper and aluminum building wire nominal dimensions and areas -- Dimensions and percent area of conduit and tubing -- Thread dimensions and tap drill sizes -- Hole saw chart -- Metal boxes -- Minimum cover requirements, 0-600 volts, normal -- Volume required per conductor -- Spacings for conductor supports -- General Electrical Tables: -- Minimum depth of clear working space at electrical equipment -- Minimum clearance of live parts -- Minimum size equipment grounding conductors for grounding raceway and equipment -- Grounding electrode conductor for alternating-current systems -- General lighting loads by occupancy -- Lighting load demand factors -- Demand factors -- For nondwelling receptacle loads -- For household electric clothes dryers -- For kitchen equipment-other than dwelling units(s) -- Demand loads for household electric rangers, wall-mounted ovens, counter-mounted cooking units, and other household cooking appliances over 1 3/4 KW rating -- Calculating cost of operating an electrical appliance -- Changing incandescent lamp to energy-saving lamp -- Partial 2011 NEC code change summary -- Field terms versus NEC terms -- Electrical symbols -- Wiring diagrams for NEMS configurations -- NEMA enclosure types -- General Reference: -- U S weights and measures -- Metric system -- Metric designator and trade sizes -- U S weights and measures/metric equivalent chart -- Explanation of scientific notation -- Useful conversions/equivalents -- Decimal equivalents -- Two-way conversion table -- Metals -- Specific resistance -- Centigrade and Fahrenheit thermometer scales -- Math Reference: -- Useful math formulas -- Circle -- Fractions -- Equations -- Natural trigonometric functions -- Trigonometry -- Conduit Bending: -- Bending offsets with trigonometry -- Rolling offsets -- Chicago-type benders: 90 degree bending -- Chicago-type benders: offsets -- Multi-shot benders: 90 degree conduit bending -- Offset bends -- 90 degree bends -- Back-to-back bends -- Three-point saddle bends -- Job-Site Reference: -- Pulley calculations -- Useful knots -- Hand signals -- Electrical Safety: -- Definitions -- Checklist -- Lock-out-tagout procedures -- Shock protection boundaries -- How to read a warning label -- Personal protection equipment guide -- Alternative Energy: -- Engine-generation systems -- Solar photovoltaic systems -- Wind turbines -- Fuel cells -- Microturbines -- Interconnected generation systems -- First Aid: -- Scene survey -- How to call for help -- Bleeding -- Ingested poisoning -- Recognizing ingested poisoning -- Care for ingested poisoning -- Shock -- Recognizing shock -- Care for shock -- Burns -- Care for burns -- Electrical burns -- Frostbite -- Recognizing frostbite -- Care for frostbite -- Hypothermia -- Recognizing hypothermia -- Care for hypothermia -- Heat cramps -- Recognizing heat cramps -- Care for heat cramps -- Heat exhaustion -- Recognizing heat exhaustion -- Care for heat exhaustion -- Heatstroke -- Recognizing heatstroke -- Care for heatstroke -- Airway obstruction -- Management of choking responsive -- Victim -- Adult cardiopulmonary resuscitation (CPR) -- Heart attack -- Recognizing a heart attack -- Care for a heart attack -- Stroke -- Recognizing a stroke -- Care for a stroke -- 2011-2013 calendars.
520 _aSynopsis: Ugly's Electrical References Is Designed To Be Used As An On-The-Job Reference. Used Worldwide By Electricians, Engineers, Contractors, Designers, Maintenance Workers, Instructors, And The Military; Ugly's Contains The Most Commonly Required Electrical Information In An Easy-To-Read And Easy-To-Access Format. Ugly's Presents A Succinct Portrait Of The Most Pertinent Information All Electricians Need At Their Fingertips, Including: Mathematical Formulas, National Electrical Code Tables, Wiring Configurations, Conduit Bending, Voltage Drops, And Life-Saving First Aid Procedures. Revised For The 2011 National Electrical Code, Ugly's Electrical References Includes Updated Coverage Of: Combination Circuits Conductor Properties Conduit Bending Conversion Tables Electrical Formulas Electrical Symbols Insulation Charts Math Formulas Metric System Ohm's Law Parallel Circuits Series Circuits US Weights And Measures Wiring Diagrams.
650 0 _aElectrical engineering
_vHandbooks, manuals, etc.
650 7 _aElectrical engineering.
_2fast
_0(OCoLC)fst01728596
650 7 _aElectrical engineering
_vHandbooks, manuals, etc.
_2sears
655 7 _aHandbooks and manuals.
_2fast
_0(OCoLC)fst01423877
700 1 _aHart, Sammie.
700 1 _aBuchanan, William C.
938 _aBrodart
_bBROD
_n13024426
_c$18.95
938 _aBaker and Taylor
_bBTCP
_nBK0008991763
938 _aYBP Library Services
_bYANK
_n3330469
029 1 _aNZ1
_b13839459
942 _cBOOK
994 _aZ0
_bSUPMU
948 _hNO HOLDINGS IN SUPMU - 94 OTHER HOLDINGS
596 _a1
999 _c10884
_d10884